ECODRIVE DKC01.1/DKC11.1 Drive Controllers
DOK-ECODRV-ASE-02VRS**-WAR1-EN-P 07.96 Description of Diagnostic Letters C... and A... 3-11
C700 Basic Load
Description:
When using MDD and MKD motors, the technical control adaptation of
the mechanical system on the digital drive relates to the activation of the
stored velocity control parameter in the motor feedback. The drive
controller signals with the message C7 that the command C7 basic load
was activated with the command "S-0-0262, command basic load."
C800 Load Basic Parameters
Description:
By pressing the S1 button on the controller with display PL or by starting
the „load basic parameters command," all parameters will be erased and
set with the default value.
The process blocks are also lost.