ECODRIVE DKC01.1/DKC11.1 Drive Controllers
2-16 Description of Diagnostic Letters F... and E... DOK-ECODRV-ASE-02VRS**-WAR1-EN-P 07.96
E831 Position Limit Value Reached During Jogging
Description:
If the position limit value monitor is activated and the drive is „IN
REFERENCE", then it will be positioned during movement in the jogging
operation on the position limit value. If the drive is positioned on the
position limit value or on the other side of the position limit value, then the
drive stays still and signals „"position limit value reached during jogging."
Remedy:
1. Move the motor back within the allowable travel area with the jog
function.
2. Turn off the position limit value monitor.
E844 Travel Limit Switch Activated
Description:
The drive was moved to one of the two travel limit switches. The reaction
of the drive regarding the travel area being exceeded would be selected
as a warning.
Exceeding the Travel Area as a Warning:
The drive brakes with maximum torque until it reaches a standstill and
stays in an activated condition at this position. If command values are
entered which lead into the allowable travel area, the drive will once again
follow these commands and the warning will disappear.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mannesmann INDRAMAT ECODRIVE DKC01.1 and is the answer not in the manual?

Mannesmann INDRAMAT ECODRIVE DKC01.1 Specifications

General IconGeneral
BrandMannesmann
ModelINDRAMAT ECODRIVE DKC01.1
CategoryController
LanguageEnglish