ECODRIVE DKC01.1/DKC11.1 Drive Controllers
DOK-ECODRV-ASE-02VRS**-WAR1-EN-P 07.96 Description of Diagnostic Letters C... and A... 3-3
C201 Invalid Parameter Block (-> S-0-0022)
Cause:
Parameters which are necessary for the operation of the drive in
operational mode are invalid.
Remedy:
Connect the drive with the PC and activate DriveTop. Select the menu
"parameter list of invalid parameters" and set valid parameters.
C202 Limit Error Parameter (-> S-0-0022)
Cause:
Parameters which are necessary for the operation of the drive in
operational mode are outside of its minimum or maximum input values.
Remedy:
Connect the drive with the PC and activate DriveTop. Select the menu
"parameter list of invalid parameters" and set valid parameters.
C203 Parameter Calculation Error (-> S-0-0022)
Cause:
Parameters which are required for operation of the drive in the operation
mode, found errors in the conversion that do not permit an orderly
operation.
Remedy:
Connect the drive with the PC and activate DriveTop. Select the menu
"parameter list of invalid parameters" and set valid parameters.
C207 Loading Error LCA
Cause:
Defective drive
Remedy:
Power down and then on again. If this in not successfull, exchange drive.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mannesmann INDRAMAT ECODRIVE DKC01.1 and is the answer not in the manual?

Mannesmann INDRAMAT ECODRIVE DKC01.1 Specifications

General IconGeneral
BrandMannesmann
ModelINDRAMAT ECODRIVE DKC01.1
CategoryController
LanguageEnglish