Page #30 background imageLoading...
Page #30 background image
ECODRIVE DKC01.1/DKC11.1 Drive Controllers
3-4 Description of Diagnostic Letters C... and A... DOK-ECODRV-ASE-02VRS**-WAR1-EN-P 07.96
C208 Invalid SSI Parameter (-> S-0-0022)
Description:
When the motors are first distributed, the parameter for absolute control
emulation is purposely invalid to ensure that the "Set Absolute
Measurement Emulator Command" will be executed after a motor is
exchanged.
Cause:
The SSI emulation was selected. The parameters required for emulation
are invalid.
Remedy:
Connect the control drive to a PC and activate DriveTop.
"Actual Position Output" menu with controller emulation type "Absolute
Controller Emulation (SSI)":
Describe "Homing Position/Offset"
Select "Absolute Control Directional Counter"
C211 Invalid Feedback Data (-> S-0-0022)
Description:
Invalid data was found while processing the parameters stored in the
motor feedback.
Causes:
1. Defective motor feedback cable
2. Defective motor feedback
Remedy:
For 1. Check the motor feedback cable
For 2. Exchange the motor

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mannesmann INDRAMAT ECODRIVE DKC01.1 and is the answer not in the manual?

Mannesmann INDRAMAT ECODRIVE DKC01.1 Specifications

General IconGeneral
BrandMannesmann
ModelINDRAMAT ECODRIVE DKC01.1
CategoryController
LanguageEnglish