ECODRIVE DKC01.1/DKC11.1 Drive Controllers
3-2 Description of Diagnostic Letters C... and A... DOK-ECODRV-ASE-02VRS**-WAR1-EN-P 07.96
C100 Communication Phase 3 Transition Check
Description:
The command "S-0-0127, C1 communication phase 3 transition
check" is activated. The drive switches from parameter mode into
operational mode.
C101 Invalid Communication Parameters (S-0-0021)
Cause:
During the switch from parameter mode to operational mode, invalid
parameters were found.
Remedy:
Connect the drive with the PC and activate DriveTop. Select the menu
"parameter list of invalid parameters" and set valid parameters.
C102 Limit Error Communication Parameters (S-0-0021)
Cause:
During the switch from parameter mode to operational mode, parameters
were found which exceed its limit value.
Remedy:
Connect the drive with the PC and activate DriveTop. Select the menu
"parameter list of invalid parameters" and set valid parameters.
C200 Communication Phase 4 Transition Check
Description:
The command C2 performs the last steps of the switch from parameter
mode to operational mode. Thereby, numerous parameter checks will be
conducted.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mannesmann INDRAMAT ECODRIVE DKC01.1 and is the answer not in the manual?

Mannesmann INDRAMAT ECODRIVE DKC01.1 Specifications

General IconGeneral
BrandMannesmann
ModelINDRAMAT ECODRIVE DKC01.1
CategoryController
LanguageEnglish