EasyManua.ls Logo

Manusa VECTOR - Appendixes; CE Declaration of Conformity

Manusa VECTOR
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
43
D00619EN - v0 SWING OPERATOR - INSTALLATION MANUAL
10.2 Installation Checklist
Compliance with safety requirements is a primary
objective for manusa, given that hundreds of thou-
sands of people in more than 70 countries pass
through our doors daily.
Risk assessment for manusa doors is not
limited to the design and industrialisation ac-
tivities carried out at our factory, but encom-
passes the entire useful life of our products,
guaranteeing the health and safety of the us-
ers at each stage of the lifecycle of the door.
Please place here the identifying
sticker for the installation
Mechanical/Electrical Elements
Compliance Non-
compliance
Not
applicable
Observations
Fixing the operator on-site
Position of the Dragging / Pushing operator
Cover and external caps
Axis and arm
Fasteners and suspension of leaves
Spring load level (EN4-EN5-EN6)
Condition of the leaves
Wiring
Low Energy parameter
Push & Go parameter
Dragging / Pushing parameter
Actuator S (spring) / M (motor) parameter
Acceleration parameter
Waiting times parameter
Lock parameter
Auxiliary I/O configuration
Peripheral controls (selector/outside key switch…)
Safety and Control Elements:
Compliance Non-
compliance
Not
applicable
Observations
Sistemas de accionamiento (radar…)
Sensores de seguridad
Documentation:
Compliance Non-
compliance
Not
applicable
Observations
Instructions manual submitted
Works delivery certificate submitted
Maintenance contract submitted

Table of Contents

Related product manuals