TROUBLE SHOOTING
1. The power can not be turned on.
(STANDBY LED does not light (STANDBY MODE))
2. The power can not be turned on.
(STANDBY LED lights ash)
Check insertion of the
8U-
110151-7/-8
STANDBY
PCB.
Check insertion of the
8U-
110151-1
U-COM UNIT.
Check whether power is
being supplied to the coil
of the STANDBY TRANS
T8501
.
Broken wire in STANDBY
TRANS
T8501
.
Malfunction of
D8501-8506.
Check whether power
is being supplied to the
D8501-8506
.
Malfunction of
U8501
,
U1001
.
Power not supplied.
Power supplied.
Power not supplied.
Power supplied.
Check whether power is
being supplied to the
F8520
.
Check each connector.
Check whether power is
being supplied to the coil of
the MAIN TRANS.
Check whether power is
being supplied to the
D8509
- 8518
.
Broken
D8509 - 8518
.
Broken wire in MAIN
TRANS.
Broken FUSE
F8520
.
Damaged P_DWN detection
circuit and
U1001
.
Damaged DC OFFSET DETECT.
Damaged OVER HEAT DETECT.
Damaged OVER CURRENT
DETECT.
STANDBY LED repeats ON/
OFF for 0.5 seconds each.
STANDBY LED repeats ON/
OFF for 0.25 seconds each.
Damaged power amplier circuit
Damaged power circuit.
Power not supplied.
Power not supplied.
Power not supplied.
(
z
1)
(
z
2)
Power supplied.
Power supplied.
Check input level,
SPEAKER connection and
SPEAKER resistance value.
21