Control panel menus 47
FIXTURE
INFORMATION
FIRMWARE
VERSION
Vxx.xx.xx Fixture software version
POWER ON TIME
TOTAL POWER ON
Display hours fixture has been powered on
since manufacture (not user-resettable)
RESETTABLE POWER ON
Display hours fixture has been powered on
since last counter reset (user-resettable)
CLEAR RESETTABLE POWER ON
Reset RESETTABLE POWER ON counter
to zero.
LAMP ON TIME
TOTAL LAMP ON
Display hours of lamp use since
manufacture
(not user-resettable)
RESETTABLE LAMP ON
Display hours of lamp use since last
counter reset (user-resettable)
CLEAR RESETTABLE LAMP ON
Reset RESETTABLE LAMP ON counter
to zero.
SET TIME ALERT
Set number of hours before LTIM lamp
lifetime warning message is displayed.
LAMP STRIKES
TOTAL LAMP STRIKES
Display number of times lamp has been
struck since manufacture (not
user-resettable)
RESETTABLE LAMP STRIKES
Display number of times lamp has been
struck since last counter reset
(user-resettable)
CLEAR RESETTABLE LAMP STRIKES
Reset RESETTABLE LAMP STRIKES
counter to zero.
AIR FILTERS
RESETTABLE AIR FILTER
Display hours fixture has been powered on
since timer was last cleared.
SET TIME ALERT Set alert timer from 0 - 750 hours.
CLEAR RESETTABLE AIR FILTER Resets AIR FILTER timer to zero.
MAC ID xx.xx.xx.xx.xx.xx Fixture’s MAC address
SERIAL NUMBER (xx)xxxxxxxxxxxx Fixture’s serial number
RDM UID 0x4D50.xxxxxxxx Fixture’s unique RDM ID
FAN SPEED* Displays speed in RPM of all cooling fans
TEMPERATURE*
Displays temperature in °C of all PCBs and
of ballast capacitor
POWER UNIT
Displays voltage at mains power input,
voltage, current and wattage at lamp
terminals, lamp status, igniter status and
lamp intensity.
EVENT LOG VIEWER Views fixture event log
DMX LIVE*
RATE
DMX transmission speed in packets per
second
QUALITY Percent of packets received
START CODE Value of the DMX start code
STROBE/SHUTTER FIXTURE ADJUSTMENTS
DMX value (0 - 255) received on each
channel
TEST
SEQUENCE*
ACTION Start / Stop / Pause Run test sequence of all functions
REPEAT On / Off Enable auto-repeat of test sequence
STATUS DURATION
Scene status information for test sequence
MANUAL
CONTROL*
RESET ACTION Click jog wheel to reset fixture
LAMP ON/OFF ACTION Manually strike/douse lamp
STROBE/SHUTTER TILT Set each effect manually.
Menu level 1 Menu level 2 Menu level 3 Menu level 4 Notes (Default settings in bold print)
Table 3: Control menus