MLI Ultra 12/2750, 12/5500, 24/5500 – User and Installation Manual
Events
With MasterBus a device can be programmed to initiate an action at another connected device. This
is very helpful in automation of your system and is done by means of event-based commands.
In the Events tab you can program the MLI Ultra to act as an event source. Events which occur
during the operation of the MLI Ultra will then trigger actions from other products.
Select an event that triggers an action, for
example Relay open.
Select the device that should act, for example the
charger.
Selectable targets are
system dependent
Select the parameter that must be changed on
the target device, for example No connection.
See command list of
the selected device
Data translates the input into an output.
• On: status changes to On at first input signal.
• Off: status changes to Off at first input signal.
• Copy: status follows input signal.
• Copy invert: status follows opposite of input.
• Toggle: status changes at 1
st
signal and back
at the 2
nd
.
Off, On, Copy,
Copy Invert, Toggle
Input
On
Off
Copy
Copy invert
Toggle