MCM Electronics iRIS8+ - Function 40 - Exit Time; Function 41 - Entry Time; Function 42 - Siren Time

Default Icon
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 10
Options - (Single digit entry required)
0 - 0 seconds 5 - 50 seconds
1 - 10 seconds 6 - 60 seconds
2 - 20 seconds 7 - 70 seconds
3 - 30 seconds 8 - 80 seconds
4 - 40 seconds 9 - 90 seconds
Options - (Single digit entry required)
0 - 0 seconds 5 - 50 seconds
1 - 10 seconds 6 - 60 seconds
2 - 20 seconds 7 - 70 seconds
3 - 30 seconds 8 - 80 seconds
4 - 40 seconds 9 - 90 seconds
Options - (Single digit entry required)
0 - 0 seconds 5 - 2 min 40 sec
1 - 10 seconds 6 - 5 min
2 - 20 seconds 7 - 10 min
3 - 40 seconds 8 - 21 min
4 - 80 seconds 9 - 42 min
Description :
This function sets the time that sectors allo-
cated as entry/exit (Function 49), exit hando-
ver (Function 50) or partial exit/entry (Function
51) will allow for exit.
Description :
This function sets the time that sectors allo-
cated as entry/exit (Function 49), exit hando-
ver (Function 50) or partial exit/entry (Function
51) will allow for entry.
Notes :
Handover sectors will only have entry time if
an exit/entry sector has been triggered rst
Description :
This function sets the maximum time for which
the internal, external and satellite sirens and
bell output will operate.
Notes:
Australian Standards AS 2201 limit the sirens to be triggered only once per section unless manually re-armed.
Noise pollution regulations in limit siren time to 5 minutes.
Example : While in program mode (Program LED ashing)
Key Sequence Operation
40 - Enter Function No.
5 - Enter Option ( 5 = 50 seconds)
on - Store Entry
Installer may now exit program mode by pressing the OFF button or continue
programming by entering a new function number
Function 41 - Entry Time Default - 30 seconds
Example : While in program mode (Program LED ashing)
Key Sequence Operation
41 - Enter Function No.
3 - Enter Option (3 = 30 seconds)
on - Store Entry
Installer may now exit program mode by pressing the OFF button or continue programming.
Example : While in program mode (Program LED ashing)
Key Sequence Operation
42 - Enter Function No.
6 - Enter Option (6 = 5 minutes)
on - Store Entry
Installer may now exit program mode by pressing the OFF button or continue programming
Function 42 - Siren Time Default - 5 minutes
Function 40 - Exit Time Default - 60 seconds