Other Features
- CHIME activates keypad buzzer for one second when a chime zone is unsealed.
- KEYBOARD panic Keyboard Panic is achieved by pressing and holding both the OFF and
ON keys together and holding for 2 secs. This is a local as well as a back
to base.
At default Keyboard Panic is disabled.
To enable keyboard panic program function 47. If programmed with a 1, the
keyboard panic is silent and will only report to the monitoring centre.
If programmed with a 2 the keyboard panic will report as well as being audible.
- KEYBOARD Duress Keyboard Duress is sent by entering your normal 4 digit code but with the
last digit incremented by 1. If your code is " 1234 " then enter "1235 ", a
duress is sent with no local alarm. A duress restore is sent when the next
valid code is entered. If the last digit of your code is " 0 " then enter a " 1 ".
Or if a " 9 " enter a " 0 ".
- 24 HOUR Inputs which are congured for 24 hour operation, when alarmed,
will send a restoral when that input is resealed and a valid user code is entered.
- MAINS FAIL Mains fail is automatically detected and reported by the control dialler. When
mains fail is detected the power LED on the Keypad will start giving a single
ash and will be beeping. The beeper will stop when any button is depressed.
After mains has been off for more than 60 minutes the dialler will send a mains
fail alarm.When mains is restored the LED will go steady again and after 30
seconds the dialler will trip and send a mains restoral. Mains fail can be
disabled by programming a 0 in Function 77. When mains fail is disabled, the
power led will remain steady during mains faill and will not report mains fail or
mains fail restoral.
- LINE FAIL Line fail is automatically detected by the control dialler. When line fail has been
detected for approx 60 + seconds the re (FAULT) LED on the Keypad will
start giving a double ash.
When the line has restored the re LED will turn off after 10 seconds. If line fail
reporting is required program a 1 in function 72. Line fail reporting will follow the
operation of the re LED.....meaning a line fail will be reported after 60 seconds
and a line fail restoral after 10 seconds.
- GSM FAIL GSM Line fail is automatically detected by the system. When GSM line fail
has been detected for approx 5 mins, the FIRE (FAULT) LED on the Keypad
will start giving a single ash. When the GSM has restored the re LED will
turn off after 3 mins. If line fail reporting is required program a 4 in function 87.
Line fail reporting will follow the operation of the re LED...
- LOW BATT Low battery is automatically detected and reported by the control dialler.
When low battery is detected the power LED on the Keypad will start giving a
double ash. After the battery voltage has been low for 30 seconds the dialler
will send a low battery report. When the battery voltage is restored to normal
the LED will go steady again and after 30 seconds the dialler will send a low
battery restoral.
If low battery occurs during the 60 minute mains fail time, then it takes
precedence over the mains fail and both events will be reported.
- TEST DIAL To test the reporting ability of the dialler a test dial may be initiated by entering
a User code and then TEST 9. When the dialler receives the handshake tones
from the monitoring station the dialler will give 3 beeps. When Tape Dial
(option 67) is enabled the dialler will give 3 beeps after dialling is completed
for the test call.