Page 12
Options : (Two digit entry required per sector)
Any sector or combination of sectors from 1 to 8
Options : (Two digit entry required per sector)
Any sector or combination of sectors from 1 to 8
Option : (Two digit entry required per sector)
Any sector or combination of sectors from 1 to 8
Function 50 - Exit and Handover Sections in ON Mode Default - none
Function 51 - Exit / Entry Sections in Partial mode Default none
Notes : Sectors programmed in this function are independent of sectors programmed as ON
mode exit / entry sectors and only have exit / entry times assigned to them when the panel is
turned ON using the Partial key.
Function 52 - Sections to operate in 24 Hour mode Default - none
Description :
This function determines whether the
sirens will be silenced for 10 seconds on
the rst key press. This allows the audible
feedback from the keypad to be heard
without the sirens interfering. (Does not
work on keypad panic)
Options : (Single digit entry required)
0 = Sirens are not disabled on rst keypress.
1 = Sirens are silenced for 10 secs on the rst
keypress.
Notes : Sectors selected will only have entry time if an exit/entry sector is triggered rst.
Function 54 - Disable Sirens On First Keypress Default - Disabled (1)
Description :
Display and / or change which sections will
have exit / handover delay.
Description :
Display and change which sections will
have exit / entry delay in Partial mode.
Description :
Display and change which sections will
operate as 24 hour inputs.
Example : While in program mode (Program LED ashing)
Key Sequence Operation
50 - Enter Function No.
02 - Enter Option (Sector 2 becomes handover)
On - Store Entry
Installer may now exit program mode by pressing the OFF button or continue program-
ming by entering a new function number.
Example : While in program mode (Program LED ashing)
Key Sequence Operation
52 - Enter Function No.
07 - Enter Options (Sector 7 is now active 24hrs)
On - Store Entry
Installer may now exit program mode by pressing the OFF button or continue program-
ming by entering a new function number.
Example : While in program mode (Program LED ashing)
Key Sequence Operation
54 - Enter Function No.
0 - Enter Option (0 = Sirens are not silenced)
On - Store Entry
Installer may now exit program mode by pressing the OFF button or continue program-
ming by entering a new function number.
Example : While in program mode (Program LED ashing)
Key Sequence Operation
51 - Enter Function No.
03 - Enter Option (Sector 3 is now Partial Exit/Entry sector)
On - Store Entry
Installer may now exit program mode by pressing the OFF button or continue programming by en-
tering a new function number.