Page 17
Options : (Single digit entry required)
1 Duress reports enabled
0 Duress reports disabled
Options : (Single digit entry required)
1 Auto - isolation enabled
0 Auto - isolation disabled
Description :
Keyboard duress may be disabled to
prevent accidental duress alarms from
private residences.
Note:
Description :
Normally if an attempt to arm the panel
with a faulted section (other than an exit/
entry section) is made the panel will give
an error beep. If this option is enabled
then faulted sections will be automatically
isolated and will be reported as such.
Duress is achieved by adding 1 to the last digit of the user code eg. 1234 becomes 1235, 6789 be-
comes 6780.
Example : While in program mode (Program LED ashing)
Key Sequence Operation
74 - Enter Function No.
1 - Enter Option (1 = reports enabled)
On - Store Entry
Installer may now exit program mode by pressing the OFF button or continue program-
ming by entering a new function number.
Function 74 - Keyboard Duress On / Off Default - Duress disabled
Function 75 - Auto-Isolate On/Off Default - Auto-Isolate disabled
Example : While in program mode (Program LED ashing)
Key Sequence Operation
75 - Enter Function No.
1 - Enter Option (1 = auto-isolation enabled)
On - Store Entry
Installer may now exit program mode by pressing the OFF button or continue programming by enter-
ing a new function number.
Example : While in program mode (Program LED ashing)
Key Sequence Operation
73 - Enter Function No.
3 - Enter Option (3 = 12hrs)
On - Store Entry
Installer may now exit program mode by pressing the OFF button or continue
programming by entering a new function number.
Description :
This sets the delay from when program
is exited till the dialler sends its rst test
report, in multiples of 4 hours.
Options : (Single digit entry required)
0 to 9 = number of 4 hr periods before the rst test
Function 73 - Delay till First test report Default - 12 hours