Page 13
Options : (Two digit entry required per sector)
Any sector or combination of sectors from 1 to 8
Options : (Four digit entry required)
Any 4 Digits (Limits 0000 - 9999)
Options : (Max of 15 digits)
The phone number may be up to 15 digits long in-
cluding pauses. Pauses (1 second) may be entered
anywhere by pressing the Partial key.
Function 55 - Silent Sections Default - None
Notes: The dialler will not dial if the account number (Function 60) or phone number 1 (Func-
tion 64) is not programmed or the account number is set to 0000. Entering the function number
and then pressing the isol + code key will clear entries for Functions 60, 62, 64 and 65.
Function 62 - Download Phone Number Default - None
Example : While in program mode (Program LED ashing)
Key Sequence Operation
55 - Enter Function No.
05 - Enter Option (Sector 5 is now silent)
06 - Enter Option (Sector 6 is now silent)
07 - Enter Option (Sector 7 is now silent)
On - Store Entry
Installer may now exit program mode by pressing the OFF button or continue
programming by entering a new function number.
Function 60 - Account number Default - None
Description :
Display and change which sections will
operate as Silent Sections ie. they will
report to the monitoring company but will
not activate the sirens.
Description :
This function is used to enter the account
number for transmission to the Central
Station.
Description :
This phone number is used by the panel
when downloading is initiated by the
MCM Connect downloading software.
Example : While in program mode (Program LED ashing)
Key Sequence Operation
60 - Enter Function No.
1234 - Enter Option (Account Number is now 1234)
On - Store Entry
Installer may now exit program mode by pressing the OFF button or continue programming by
entering a new function number.
Example : While in program mode (Program LED ashing)
Key Sequence Operation
62 - Enter Function No.
02 - Enter Area Code
part - Enter a 1 second Pause
218067 - Enter Phone number (047p2180676)
On - Store Entry
Installer may now exit program mode by pressing the OFF button or continue programming by
entering a new function number.