Page 28
Reporting codes Contact ID Function 67=4
Contact ID Format
SSSS 18 E TTT PP NNN
Where SSSS = Four Digit Account Number
18 = Unique Format Identier
(Not Displayed or Printed)
E = Event
1 = New Event or Opening
3 = New Restore or Closing
TTT = Event Code
120 = Panic Alarm
121 = Duress Alarm
130 = Burglar Alarm
301 = AC Power Loss
302 = Low Battery
401 = Open/Close by User
570 = Zone Bypass
602 = Periodic Test Report
New Codes
137 = Tamper Alarm
305 = System Reset
351 = PSTN line Fail
352 = GSM Fail
406 = Cancel by User
407 = RF Remote Arm/Disarm
408 = Quick Arm
409 = Open/Close by keyswitch
306 = Panel Programming changed
309 = Battery Test Failure
311 = Battery Missing/Dead
602 = Periodic test report
PP = Area or Partition Number
NNN = Section Number or User Number
Examples of Reporting Note: Checksum is omitted for clarity
1234 18 1 120 00 000 Panic Alarm
1234 18 1 121 00 005 Duress Alarm by user 5
1234 18 1 130 01 001 Section 1 alarm in area 1
1234 18 1 130 01 002 Section 2 alarm in area 1
1234 18 3 301 00 000 AC Fail restore
1234 18 1 302 00 000 Low battery alarm
1234 18 1 401 00 001 Open message with user code 1
1234 18 1 602 00 000 Test Report