Page 6
Program Readback
With the full range of panels there are basically two methods of reading back information that has
previously been programmed. The rst method allows information that is serial in format to be read
sequentially ie. phone numbers, while the second method allows all selections to be seen at once
ie. sectors assigned as E/E. These are explained below.
SEQUENTIAL READBACK
Whilst in PROGRAM mode, if an option is entered followed by the TEST key then that options
setting will be read back using the LEDs on the programmer as follows :
" LED " " INDICATES DIGIT "
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
Partial 9
On 0
Auxiliary Pause
Example
For this example Function 60 is already programmed as 0199
If you wish to check Function 60
Enter the function number 6 0 followed by the TEST key.
( whilst in program mode )
ON LED will light accompanied by a beep (digit 0)
Then number 1 LED accompanied by a beep (digit 1)
Then PARTIAL LED accompanied by a beep (digit 9)
Then another beep with PARTIAL LED still lit (digit 9)
Then beep beep and the PROGRAM LED ashing again
(test completed ready for next function).
PARALLEL READBACK
For Functions 31 - 36, 49, 50, 51, 52, 55, 56, 61, 76, 82.
When the function number is entered the previously selected sections will
ash. If at this point the On button is depressed no changes will be made
and the program LED will be ashing again.
To de-select a section re-enter that section number and the section LED
will extinguish.