Page 26
Description :
This function may be used to prevent the
user from being able to arm the panel
Options :
0 = Arming can be performed.
1 = Arming is disabled.
Function 95 - Arming Lockout Default - Arming enabled
Example : While in program mode (Program LED ashing)
Key Sequence Operation
95 - Enter Function No.
1 - Enter Option (1 = Panel cannot be armed by user code)
On - Store Entry
Installer may now exit program mode by pressing the OFF button or continue programming by en-
tering a new function number.
Example : While in program mode (Program LED ashing)
Key Sequence Operation
96 - Enter Function No.
1 - Enter Option (1 = ring detect only)
On - Store Entry
Installer may now exit program mode by pressing the OFF button or continue programming
by entering a new function number.
Notes :
Downloading can be initiated by one of the three methods listed below :
1. Ring Detect - The panel will dial back using the download phone number
(Function 62) if it receives three calls, of six rings duration (4-8), within a
90 second period.
2. Master code initiated - Entering the User Master Code + test 8 will cause the
panel to dial as if it had detected the correct ring sequence.
3. Tech code initiated - Tech code + test 80 will cause the panel to dial as if
it had detected the correct ring sequence.
Description :
This function determines how a down-
load / upload session is initiated.
Options : (Single digit entry required)
0 = Download disabled
1 = Ring detect only
2 = Ring detect or Tech code only
3 = Ring detect, Master code or Tech code
4 = Tech code only
5 = Master or Tech code only
Function 96 - Download Conguration Default - 5