EasyManua.ls Logo

MCM Electronics iRIS8+ - Function 43 - Partial Mode; Function 47 - Keypad and Remote Panic Audible; Function 49 - Exit;Entry Sections in on Mode

Default Icon
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 11
Description :
Partial mode sets up a preprogrammed
list of sections which are automatically
isolated when the unit is turned on using
the partial key.
Description :
This function determines whether the
keypad panic activation (holding the
ON and the OFF keys depressed at
the same time for 3 seconds) or keyfob
panic activation (holding buttons 1 & 2
on the remote keyfob momentarily) will
cause the sirens to sound in addition to
reporting to the monitoring company, only
report or disabling the panic function.
Description :
This function allows the display and or
changing of those sections which will
have the exit/entry delays dened in
Functions 40 and 41.
Options : (Two digit entry required per sector)
Any sector or combination of sectors from 1 to 8
Options : (Single digit entry required)
0 = Panics disabled (keypad & remote)
1 = Silent Panic (report only)
2 = Audible Panic (Sirens) and report.
Options : (Two digit entry required per sector)
Any sector or combination of sectors from 1 to 8
Function 47 - Keypad & Remote Panic Audible Default - Disabled
Example : While in program mode (Program LED ashing)
Key Sequence Operation
47 - Enter Function No.
1 - Enter Option (Panics now silent)
On - Store Entry
Installer may now exit program mode by pressing the OFF button or continue programming by enter-
ing a new function number
Example : While in program mode (Program LED ashing)
Key Sequence Operation
49 - Enter Function No.
0208 - Enter Option (Sector 2 is removed and section 8 is added)
On - Store Entry
Installer may now exit program mode by pressing the OFF button or continue programming by enter-
ing a new function number.
Function 49 - Exit/Entry Sections in ON Mode Default - Sectors 1 & 2
Example : While in program mode (Program LED ashing)
Key Sequence Operation
43 - Enter Function No.
050708 - Enter Options (Sectors 5, 7 & 8 will be isolated)
On - Store Entry
Installer may now exit program mode by pressing the OFF button or continue program-
ming by entering a new function number
Function 43 - Partial Mode Default - No sections programmed.

Table of Contents