Page 18
Description :
If enabled, this function will allow AC
Mains Fail reporting
Options : (Single digit entry required)
0 - AC Mains Fail reporting disabled
1 - AC Mains Fail reporting enabled
Example : While in program mode (Program LED ashing)
Key Sequence Operation
77 - Enter Function No.
0 - Enter Option ( 0 = AC Mains Fail Reporting disabled)
On - Store Entry
Installer may now exit program mode by pressing the OFF button or continue programming by
entering a new function number.
Function 77 - Report AC Mains Fail Default - Enabled
Note:
When Mains Fail reporting is disabled, the AC fail detect is also disabled, this means the power led
will not ash when there is no AC power
Description :
This function sets how long the strobe
will be active after an alarm is generated
Note :
When disabled 0 the strobe output will
remain active until the system is dis-
armed.
Options : (Single digit entry required)
0 - Disabled ( Strobe stays on till disarmed)
1 - 5 min
2 - 10 min
3 - 30 min
4 - 1 hr
5 - 2 hrs
6 - 3 hrs
7 - 6 hrs
8 - 12 hrs
9 - 24 hrs
Example : While in program mode (Program LED ashing)
Key Sequence Operation
78 - Enter Function No.
2 - Enter Option ( 2 = Strobe Timeout 10 minutes)
On - Store Entry
Installer may now exit program mode by pressing the OFF button or continue programming by
entering a new function number.
Function 78 - Strobe Timeout Default - Disabled
Function 76 - Multi-Report (Multi-Break) Default - None
Example : While in program mode (Program LED ashing)
Key Sequence Operation
76 - Enter Function No.
01 - Enter Option (01 = sector 1)
02 - Enter Option (02 = sector 2)
On - Store Entries
Installer may now exit program mode by pressing the OFF button or continue
programming by entering a new function number.
Note:
This option will not give multi triggering of sirens to a section but will give multi reporting. The sec-
tion LED will latch on the rst alarm for that section.
Description :
Display and change which sections will
report input condition changes when
armed.
Options : (Two digit entry required per sector)
Any sector or combination of sectors from 1 to 8