EasyManua.ls Logo

Mec 2033ES - Page 74

Mec 2033ES
260 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
October 2008 "2033ES / 2633ES" Service & Parts Manual - ANSI Specifications
Page 4-20
LED Status Description
Fault Output is open or short, or output voltage is over a limit.
Otherwise, output terminals are reversed.
All 3 LED lamps blink once
simultaneously.
All 3 LED lamps blink twice
simultaneously.
Input voltage is out of the range
All 3 LED lamps blink three
times simultaneously.
The internal temperature of the charger exceeds a limit.
All 3 LED lamps blink four
times simultaneously.
Output current exceeds a limit.
Warning
100% LED lamp blinks. Battery pack has a bad cell.
ART_2185
Please see service manual for additional information.
100% charged
75% to 100% charged
50% to 75% charged
0 to 50% charged
ON
ON
ON
50%
Blinking
ON
ON
Blinking
OFF
ON
Blinking
OFF
OFF
75% 100%
BATTERY CHARGER
INDICATOR
90826
INPUT INTERLOCK OUTPUT
DO NOT CHANGE THE INPUT VOLTAGE
BEFORE “THREE LEDS TURN OFF”
LEDs
To determine if a charger is malfunctioning, identify the problem from the following list and refer to
the appropriate section for detailed instructions.
1.) Charger does not turn on
2.) All 3 LEDs blink simultaneously
3.) 100% LED blinks while 50% and 75% LEDs are “OFF”
4.) Batteries do not fully charge
5.) The AC supply circuit breaker or fuse is blown
If the problem is not listed above, refer the problem to a qualified service agent for additional
trouble shooting procedures.

Table of Contents

Related product manuals