October 2008 "2033ES / 2633ES" Service & Parts Manual - ANSI Specifications
Page 2-12
CONTINUITY CHECKS
Check Toggle Switch
Disconnect wires and connect one probe of ohm meter to the connection on toggle switch
and the other probe on the other connection.
When toggle is open, there should be no reading, and when closed there should be a low
reading.
Check Selector Switch
Disconnect wires and connect one probe of ohm meter to common and the other to nor-
mally open terminal.
With the switch flipped, there should be a low resistance.
Check Emergency Stop Button
Disconnect wires and connect one probe of ohm meter to connection on button and other
probe on other connection.
There should be no reading with the button pressed and a low resistance with it reset.
Check Limit Switch Operation
Disconnect wires.
With one probe of ohm meter to common and other probe to open contact, move limit
switch arm. Low resistance should be seen.
With one probe of ohm meter to common and other probe to closed contact, low resis-
tance should be seen. Move limit switch arm and no resistance should be seen.