2.2 Specifications
Modes of testing:
L1:
L2:
Alt:
Diff:
NEXT:
Reflection test of cable connected to
socket L1 versus built-in balancing
network
Reflection test of cable connected to
socket L2 versus built-in balancing
network
A reflection test is carried out alternately on
cables connected to sockets L1 / L2
Measurement of difference between
cables connected to sockets L1 and L2
Location of crosstalk between cables
connected to sockets L1 and L2
Pairs to be connected: 2
Modes of operation:
Single
Cont
Average
IFL
Single test
Continuous testing
Averaging of up to 256 test results
for intermittent faults (I
ntermittant Fault
L
ocation)
Measuring ranges at
v
/
2
= 100 m/µs
50, 100, 200, 400, 1000, 2000 m
4, 7.5, 15, 30 km
(zoomed 5 m)
Zoom factors (X direction) 1, 2, 5, 10, 20
(depending on range of measurement)