SDM-9XXX Series Hardware Installation Guide
3-20 Memotec Inc.
3.8 Installing the Unit in a Rack
3.8.1 Installing the SDM-9120 in a rack
A rackmount kit is provided with each SDM-9120 unit for optional rackmount installation
of the unit chassis (Ordering part number KT-0021088). Details about the rackmount kit
are provided on “Rackmount Kit” on page 4-11.
To assemble the rackmount kit and install the unit in a rack:
1. Screw the brackets to the front or rear of the SDM-9120 unit using 2 small screws
along the bottom of each bracket, as shown in
Figure 3-8.
2. Optionally, you can add an handle to the bracket by aligning the handle with the holes
and screw the handle using 2 provided screws.
3. Carefully insert the SDM-9120 unit with the attached brackets into the rack. Secure
the front of each bracket onto the rack using two mounting screws with washers.
3.8.2 Installing the SDM-9220/9230 in a rack
A rackmount kit is provided with each SDM-9220/9230 unit for optional rackmount
installation of the unit chassis (Ordering part number 100-1086-001). Details about the
Figure 3-8: SDM-9120 Rackmount Brackets
Install each bracket
into pre-drilled holes
on side of unit.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Memotec NetPerformer SDM-9230 Series and is the answer not in the manual?

Memotec NetPerformer SDM-9230 Series Specifications

General IconGeneral
BrandMemotec
ModelNetPerformer SDM-9230 Series
CategoryNetwork Hardware
LanguageEnglish

Related product manuals