032 Duress Alarm
Activates when a duress passcode is entered
and deactivates when the duress alarm is
reset.
033 System Part Set
Activates when the system is part set and
deactivates when the system is fully set or
unset.
034 Battery Fault
Activates when a battery fault occurs and
deactivates when the battery fault is cleared.
035 Set Fail
Activates when the system fails to set and
deactivates when the set fail condition is reset
by the user.
036 System Open
Activates when the system is unset,,
deactivates when the system is fully set or
part-set.
037 New Alarm
Activates for 2 seconds when any circuit
causes a new alarm condition.
038 24hr Circuits Omitted
Activates when one or more 24 Hour circuits
are omitted.
039 Modem Lockout
Activates when the modem is locked-out (four
failed attempts). Deactivates when a master
user passcode is entered or after 4 hours.
040 Chime Mimic
Activates for 2 seconds when a circuit that is
programmed as "chime" is activated.
041 Shunt Group Active
Activates when the shunt code has been used
to shunt a group of circuits. Deactivates when
the shunt code is used again to re-instate the
circuits.
042 Timed Output
Activates when a "Monitored" circuit is
triggered and remains active for the duration
of the "Monitor Delay" see System Timers.
043 Abort
Activates for 5 seconds after an alarm is
aborted by the user. The period in which the
alarm may be aborted is set by the "Abort
Delay" see System Timers.
No Type/Description
044 General Fault
Activates during battery fault or when the
system is prevented from being set.
Deactivates when all faults are cleared.
045 Battery Test
Activates for 1 minute on the hour every hour.
This output is used to test the battery in remote
PSU’s using a 519FM monitor PCB).
046 Service Call
Activates when the system is on-line with a
remote PC and Lineload software.
047 System Full Set
Activates when all areas within the system are
set and deactivates when any area is unset.
050 PC Output 1
This output type is switched on and off via the
PC and Lineload software.
051 PC Output 2
This output type is switched on and off via the
PC and Lineload software.
052 Sounder Control
Normally used as the 0V connection for an
extension loudspeaker so that only system
alarm tones are generated. Only suitable for
Panel Outputs 1 and 2.
054 Call Engineer
Activates when the system requires an
"Engineer Reset", deactivates when the
system is reset by the engineer or "Remote
Reset".
055 Always Off
Never activates.
100 - 113 Circuit Mimic
Will mimic (active when circuit is active) circuits
01 to 14 respectively.
200 - 213 Circuit Alarms
Active when a circuit causes an alarm, or is
activated during a walk test, for circuits 01 to
14 respectively.
Following a wallk test, the operator can
confirm the operation of all the appropriate
circuits at a mimic panel. The control unit
clears these indications when the operator
enters a valid passcode.