Log Event Codes
Reset User Code 1 [2.0]
This option allows the installation engineer to reset
the master user (user 01) back to the factory
default code of “5678". This feature is useful when
the master user has forgotten their passcode or
has accidentally changed it without realising. This
operation is logged.
Start Call Back [2.A]
If the system is fitted with a digi-modem, it is
possible for the installation engineer to initiate an
upload sequence to a remote site (normally the
alarm company). Once the communication link is
established with the remote site, data can be sent
and received from the control panel. This feature is
only compatible with Menvier Lineload software
version 2.5 or above.
40
Engineer's Menu 2 TS590 Installation Manual
LCD Description
PANEL LID TAMPER
Control panel lid removed.
PART SET A/B/C
System Part-Set using one of the A, B, or C buttons.
PASSCODE 00-15
User passcode entered. (00-15).
REINSTATEMENT
Time and date for reinstatement.
RELEARN REQUIRED
Hardware relearn required see page 34.
REM REMOVED 01-04
Remote Keypad removed from system.
REM SERVICE CALL
Remote service call via “Lineload” software and PC.
REM TAMPER 01-04
Remote Keypad cover removed.
REMOTE ADDED 01-04
Remote Keypad added to the system.
REMOTE RESET
System reset by “Remote Reset” passcode.
SERVICE CALL END
Remote service call finished.
SERVICE REQUIRED
Service required
SET FAIL
System failed to Set.
SYSTEM OPEN
System fully unset.
SYSTEM RE-ARMED
System re-armed all healthy circuits.
SYSTEM SET
System fully set.
TAMPER 00
Short circuit on ID loop.
TAMPER 01-14
Tamper alarm from circuit.
TEST CCTS OFF
All circuits taken off “Test”
TEST FAIL 01-14
Circuit failed during “Test”.
Press ENT to
Reset User 1 ?
to reset user 1
0
ENT
Engineers menu 2
Select Option :-
LCD
Reset User Code Flowchart