Log Event Codes
39
TS590 Installation Manual Engineer's Menu 2
LCD Description
AC OFF
Mains power removed.
AC RESTORED
Mains power restored
ACTION ALARM
Alarm activated when system is part-set.
ALARM 01-14
Full alarm from circuit (01-14).
AUX/BELL TAMPER
Auxiliary tamper activated.
AUXILIARY 01-14
Auxiliary circuit activated.
BATTERY FAULT
Battery fault (voltage below 10.5V).
BELLS REARM
Time and date of bells reinstatement. Separate from System re-arm.
BELL TESTED
External bell and strobes tested.
CALL BACK No. 01-03
Modem making a call back to remote PC.
CCT OMITTED
Circuits omitted by the user at time of Setting.
CCTS ISOLATED
24Hr group omitted during the unset condition.
CCTS TESTED 01-14
The number of circuits tested during Walk Test.
CODE TAMPER
Code tamper from keypad 01-04
COMMS ACTIVE
Plug-on digicom active.
COMMS FAILED
Plug-on digicom failed to communicate.
COMMS SUCCESSFUL
Plug-on digicom communicated successfully.
DATE CHANGED
System Date changed.
DEFAULT CODE
User passcode (01) reset to 5678 by the engineer.
DELAY ALARM 01-14
Delayed alarm during a part-set condition.
DURESS 01-15
Duress alarm from user passcode (01-15).
ENTRY 01-14
Entry timer started by circuit (01-14).
ENTRY ALARM 01-14
Entry timed-out alarm from circuit (01-14).
FACTORY RESTART
System “Factory Restarted”.
FIRE ALARM 01-14
Fire alarm circuit activated.
FIRST KNOCK 01-14
The first activation of a Double Knock circuit.
FUSE BLOWN 01
Control Panel 12V Auxiliary Fuse blown.
KEY SWITCH 01-14
Keyswitch operation from circuit (01-14).
LINE FAULT
Telephone line fault detected.
LINE RESTORED
Telephone line fault restored.
LOCKSET LOCKED
Lock switch placed in “Locked” position
LOCKSET RESTORED
Lock switch placed in “unlocked” position.
MODEM LOCK-OUT
Modem failed to communicate.
NO EVENT
No log event.
OMITS REMOVED
Previously omitted circuits reinstated.

Table of Contents