36 Entry Confirmation After 2 circuits
When programmed as “Yes” the control unit
sends a confirmed alarm if an intruder
activates two separate zones after the entry
timer expires. If the control unit is in alarm
before the user starts entry then only one
subsequent zone violation is required.
Note: Select this option if you are installing a
DD243:2002 para 6.4.5 compliant system
and the user must unset the system with a
proximity detector (“Portable ACE”).
Whe programmed as “No” the control unit
sends a confirmed alarm if the intruder
activates one zone after the entry timer
expires. This option does not comply with
DD243:2002.
+
If you program Confirmation After Entry
as “No” then the setting of this option has
no effect.
37 Unconfirmed Alarm User Reset
When programmed as “Yes” then users can
reset the system after an unconfirmed alarm.
When programmed as “No” then an engineer
or the ARC must reset the system after an
unconfirmed alarm.
(Default = “Yes”)
38 Keypad PA On
When programmed as “Yes” then the user can
start a PA alarm by pressing keys 1 and 3 at the
same time. Program as “No” to remove this
option.
(Default = “No”.)
33
TS590 Installation Manual Engineer’s Menu 1
Configuration
Enter Number >--
User reset
Option 07 - Yes
User reset
Option 07 - No
to alternate Yes and No
Option No.
9
B
ENT
Enter configuration No.
e.g. 07 for user reset
ENT
Engineers menu 1
Select Options :-
LCD
Configuration Flowchart