SMART TACH & SPEED
4-14
SMART TACH & SPEEDOMETER
osl18
Tachometer Calibration
[DOWN]
[UP]
[SAVE]
CALIBRATION
FUEL TANK CAPACITY
CAPACITY = XX.XX
Add the capacity of the fuel tank.
Press + or to select. Press MODE
to save.
CALIBRATION
[EDIT][SKIP]
CALIBRATING
FUEL TANK CALIBRATION
EMPTY TANK
THEN PRESS PLUS (+) BUTTON
[DFLT]
[SAVE]
[SKIP]
CALIBRATING 1/4 VALUE
[DFLT]
[SAVE]
[SKIP]
THEN PRESS PLUS (+) BUTTON
FILL TO X.X G.
CALIBRATING 1/2 VALUE
[DFLT]
[SAVE]
[SKIP]
THEN PRESS PLUS (+) BUTTON
FILL TO X.X G.
CALIBRATING 3/4 VALUE
[DFLT]
[SAVE]
[SKIP]
THEN PRESS PLUS (+) BUTTON
FILL TO X.X G.
CALIBRATING FULL
[DFLT]
[SAVE]
[SKIP]
THEN PRESS PLUS (+) BUTTON
FILL TANK TO FULL
This calibration accurately adjusts the
fuel level sending unit in the fuel tank.
NOTE: If the fuel tank is not calibrated,
fuel range cannot be displayed
Press MODE to skip to the next dis-
play. Press + (edit) to calibrate the fuel
tank.
Pressing DFLT (default) during edit will
return to original value setting
Calibrate the fuel tank as follows:
1. Empty the fuel tank, Press + to save
2. Fill tank to 1/4 full, Press + to save.
3. Fill tank to 1/2 full, Press + to save
4. Fill tank to 3/4 full, Press + to save.
5. Fill tank to full, Press + to save.
The fuel tank is now calibrated
(continued on next page)

Other manuals for Mercury SMARTCRAFT

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mercury SMARTCRAFT and is the answer not in the manual?

Mercury SMARTCRAFT Specifications

General IconGeneral
BrandMercury
ModelSMARTCRAFT
CategoryBoating Equipment
LanguageEnglish

Related product manuals