Installers manual 10.03.02-R03 (201058) EN SDA-04 (SW 5.xx) - SDA-04DCB2 (SW 22.00) Page 31 of 55
(safety sensors)
41
-
Sensor 1 mode
(I=29)
0=safety sensor / 1=Opening sensor
(n.c.)
0/1
0
42
62
Sensor 2 mode
(I=32)
0=safety sensor / 1=Closing sensor
(n.c.)
0/1/2
0
43
-
Sensor 3 mode
(I=25)
0=Active while closing / 1=Active
while closing
0/1
0
44
-
Sensor 4 mode
(I=26)
0=Active while closing / 1=Active
while closing
0/1
1
45
55
DMS
0=Door stops only at blocking
1..9: 1=Least sensitive, 9=most
sensitive
0/1..9
5
46
87
DMS open/close
factor
0=Opening DMS 3,25 times closing
DMS; 9=Opening DMS the same as
closing DMS
0..9
5
50
6
Start speed
1= Threshold speed; 9=220mm/s
1..9
5
51
3
Speed during
opening
1= Treshold speed; 9=800mm/s
1..9
5
52
4
Speed during
closing
1=Treshold speed; 9=400mm/s
5
53
5
Endspeed at
opening
1=Treshold speed; 9=120mm/s
1..9
3
54
-
Endspeed at
closing
1=Treshold speed; 9= 120mm/s;
0=same as parameter 53
0/1..9
0
55
89
Slow mode to
beginning position
Extra distance to run in slow mode
measured in cm
0..50
0
56
86
Slow mode to end
position
Extra distance to run in slow mode
measured in cm
0..50
0
57
78
Extra force during
closing
0=Off / 1..9= On (1=weak, 9=strong)
0/1..9
0
58
77
Boost at the start
of closing
0=Off / 1..9= On (1=weak, 9=strong)
0/1..9
0
70
79
Output relay 1
function
0=lock / 1..9=see parameter 74
0/1/2/3/
4/5/6/7/8
9 (DCB)
10/11
0
71
66
Relay 1 mode
0=normally open, 1= normally closed
0/1
0
72
80
Output relay 2
function
0=interlock / 1..9=see parameter 74
0/1/2/3/
4/5/6/7/8
9 (DCB)
10/11
0
73
67
Relay 2 mode
0=normally open, 1= normally closed
0/1
0
74
63
Output relay 3
function
0=Off / 1=Door open / 2=4 sec
before and during closing / 3=door
semi-open / 4=Fault /
5 monitor check fotocell 1 /
6 monitor check fotocell 1 & 2 /
7=interlock output / 8=puls 500
msec at start opening / 9=battery
empty (DCB) / 10=not closed and not
blocked / 11=door not closed or any
error
0/1/2/3/
4/5/6
7/8
9 (DCB)
10/11
0
75
68
Relay 3 mode
0=normally open, 1= normally closed
0/1
0
76
58
Motorlock
0=input 1 activates lock / 1=input 1
activates lock and motorlock
0/1
0
77
60
Always locked
1=yes /0=Only at ‘Lock’ or one-way
0/1
0