Installers manual 10.03.02-R03 (201058) EN SDA-04 (SW 5.xx) - SDA-04DCB2 (SW 22.00) Page 31 of 55
0=safety sensor / 1=Opening sensor
(n.c.)
0=safety sensor / 1=Closing sensor
(n.c.)
0=Active while closing / 1=Active
while closing
0=Active while closing / 1=Active
while closing
0=Door stops only at blocking
1..9: 1=Least sensitive, 9=most
sensitive
0=Opening DMS 3,25 times closing
DMS; 9=Opening DMS the same as
closing DMS
1= Threshold speed; 9=220mm/s
1= Treshold speed; 9=800mm/s
1=Treshold speed; 9=400mm/s
1=Treshold speed; 9=120mm/s
1=Treshold speed; 9= 120mm/s;
0=same as parameter 53
Slow mode to
beginning position
Extra distance to run in slow mode
measured in cm
Slow mode to end
position
Extra distance to run in slow mode
measured in cm
Extra force during
closing
0=Off / 1..9= On (1=weak, 9=strong)
Boost at the start
of closing
0=Off / 1..9= On (1=weak, 9=strong)
0=lock / 1..9=see parameter 74
0/1/2/3/
4/5/6/7/8
9 (DCB)
10/11
0=normally open, 1= normally closed
0=interlock / 1..9=see parameter 74
0/1/2/3/
4/5/6/7/8
9 (DCB)
10/11
0=normally open, 1= normally closed
0=Off / 1=Door open / 2=4 sec
before and during closing / 3=door
semi-open / 4=Fault /
5 monitor check fotocell 1 /
6 monitor check fotocell 1 & 2 /
7=interlock output / 8=puls 500
msec at start opening / 9=battery
empty (DCB) / 10=not closed and not
blocked / 11=door not closed or any
error
0/1/2/3/
4/5/6
7/8
9 (DCB)
10/11
0=normally open, 1= normally closed
0=input 1 activates lock / 1=input 1
activates lock and motorlock
1=yes /0=Only at ‘Lock’ or one-way