Technical characteristics
52 100,000 cts digital multimeters
Technical characteristics of the MTX 3292, MTX 3293 (continued)
Frequency
Main frequency
measurement
The user can measure a voltage or a current and its frequency simultaneously.
AC
signals
Range
Resolution
Protection
Accuracy
10 to 100 Hz
0,001 Hz
1414 Vpk
0,02 % ± 10 D
100 to 1000 Hz
0,01 Hz
1000 Hz to 10 kHz
0,1 Hz
10 to 100 kHz
1 Hz
100 to 1000 kHz
10 Hz
1 MHz to 5 MHz
100 Hz
Range
Sensitivity (applicable only to rectangular signals)
100mV
1V
10V
100V
1000V
0 Hz to 10 Hz
-
-
-
-
-
10 Hz to 200 kHz
10 %
20 to 5%
5 %
5 %
5 % ()
200 to 500 kHz
20 %
5 %
5 to 2 %
5 to 10 % ()
5 % ()
500 to 1000 kHz
-
5%
2 %
10 %
5 % ()
1 MHz to 5 MHz
2 à 50 %
20 % ()
() Freq [kHz] limited to: 15,000/U input [V]
U input [V] limited to: 15,000/Freq [kHz]
() limited to 200kHz
The measurement is made by capacitive coupling.
Manual selection of freq. range, F <200kHz (default) or F >200kHz
by a short press.
Input resistance: 10M (Freq <100Hz)
Max. acceptable permanent voltage: 1,414 Vpk, see ()
Protection by varistors on the voltage input.