4.0 Configuration
4.7.5 GPS > Recorder
The IPn4G can log the last 200 GPS events and store them in non-volatile memory. These
events can then be viewed within the WebUI, on a map, or sent to a remote server.
Image 4-7-6: GPS > GPS Recorder Service
Status
Use the Status parameter to enable the GPS recording functionality
of the IPn4G.
Values (selection)
Disable
Enable GPS Recorder
Position Items
Specify the maximum number of events to be recorded by the
IPn4G. Currently this is a fixed value at 2000 entries.
Values (selection)
Max 2000 Items
Record Interval
Define the interval at which the IPn4G will record GPS data. If there
is no valid data available at the specified time, the unit will wait until
the next time valid information is received.
Values (seconds)
300