Chapter 2 System Components
2-26 HAWK MV-4000 Smart Camera Guide
To avoid losing two of the available three output signals, you can connect an output signal
to a sinking input as follows. Note that, in this configuration, you will need to connect an
external pull-up resistor. Since your HAWK MV-4000 output signals can sink up to 50 mA,
use the documentation of your sinking device to calculate the required resistance for your
external pull-up resistor (if necessary).
(Equivalent circuit only.)