2-14
ARC-6000
98-05012
R3
RECALLING THE FULL LOAD VALUE
When PRODUCT VOL. and OPERATE mode are
selected, the Full Load Value of the vehicle can be
recalled by holding the INC switch up for at least three
seconds.
SETTING A LOAD VALUE LESS THAN FULL LOAD
If a full load is not taken aboard the vehicle, the actual
amount loaded can be set without changing the "Full
Load Value". First recall the Full Load Value as
explained in the previous section, then use the INC/DEC
Switch to set the actual volume loaded into the tank.
LOW P RODUCT ALARM
The Low Product Alarm alerts the operator when the
Product Volume, displayed on the console, reads 10%
of the Full Load Capacity. The console beeps for three
seconds and displays the message "LO PROD". Console
control functions are not affected by this alarm. To
disable the alarm, do not recall the Full Load Capacity.