5-1
98-05012
R3
ARC-6000
ERROR CODE CAUSE REMEDY
Trouble shooting of the MIDWEST TECHNOLOGIES Control System begins
when the Control Console senses a problem or inconsistency in the system.
When this happens, the Control Console alerts the operator with a visual and
audible alarm. The following chart presents the error messages that may appear
on the display and possible causes and remedies.
Err 0
Err 1
Pump L
(TOO FAST)
Err 0/Pump L: reset flow
meter Cal#.
Err 0/Dist. Cal#: reset
distance Cal#.
Err 0/Boom #: reset boom
widths (including boom
width C.
Slow down, or check
hydraulic flow to a hydrauli-
cally driven pump.
Change to larger nozzles or
slow down.
Reduce sparging or increase
pump output.
A required calibration number
is set to zero.
Sometimes caused by poor
power connections at the
battery.
Pump servo valve, or liquid
flow control valve is fully
open, or is no longer respond-
ing to an open signal, and the
system cannot meet the rate
called for.
Traveling too fast for desired
application rate.
Nozzles are too small for rate
and speed. (pressure will read
HIGH).
Too much product being
diverted to sparge.