3-5
98-05012
R3
ARC-6000
GSO Switch "GSO Speed" Ground Speed Speed controlled to
"OFF" 5 mph 6 mph 6 mph
"OFF" 5 mph 4 mph 4 mph
"ON" 5 mph 6 mph 6 mph
"ON" 5 mph 4 mph 5 mph
When the GSO Switch is "ON" (closed), and the actual
ground speed is less than the "GSO Speed", the ARC
automatically uses the "GSO Speed" value to control
the application rate. If the actual ground speed in-
creases above the preset "GSO Speed", the control
console will revert to controlling application rate on
the basis of the actual ground speed.
Examples:
M
id-T
Mid-T
ech
CAUTION: When traveling at a speed slower than
the GSO speed setting, this feature will cause the
product to be applied at a rate consistent with the
GSO speed, rather than the true ground speed.
Caution must be exercised when operating in this
mode as serious over application can occur, if not