Installation
*INSTALLATION*
111
Installation
In order to reduce the risk of damage from condensation, the
furniture in the area around the commercial dishwasher should be
designed for commercial use.
The commercial dishwasher must be installed in a secure and level
position. Any unevenness in the floor level and height of the machine
can be compensated for by adjusting the four feet.
If the dishwasher is to be installed next to other appliances and
furniture or in a recess, an installation space measuring at least
600mm wide and 600mm deep is required.
Building under
To ensure the stability of built-under commercial dishwashers,
these units may only be installed beneath a continuous countertop
that is bolted to adjacent cabinetry.
If the dishwasher is to be installed beneath a continuous countertop,
an installation space measuring at least 600mm wide, 600mm deep
and 820mm high is required.
When adjusting the dishwasher height, the feet must not be
unscrewed by more than 60mm.
If the dishwasher is fitted with a lid, it can be removed as follows:
Remove both securing screws on the back of the commercial
dishwasher with a screwdriver.
Open the door.
Unscrew the left and right fastening screws with a screwdriver.
Lift the machine lid upwards to remove.