User Guide
Steritest
®
Symbio Pumps

Table of Contents

Questions and Answers

  • A
    Adriana GutierrezAug 4, 2025
    How to troubleshoot a Millipore Sigma Steritest Water Pump that won't start?
    • M
      Miss Hayley ClarkeAug 4, 2025
      If your Millipore Sigma Water Pump isn't starting, there are a few things to check: * Make sure the pump is properly connected to the communication hub, and that the communication hub is connected to a power source. * Verify that the communication hub is switched on. The on/off switch is located on the front of the hub (position l ). * If the communication hub is on but the light on the on/off switch is off, and the hub is connected to a power source, inspect the communication hub fuses.
  • G
    Greg MendozaAug 8, 2025
    What to do if liquid doesn't flow correctly from the drain tray of my Millipore Sigma Steritest?
    • A
      aprilmartinAug 8, 2025
      If the liquid isn't flowing correctly from the drain tray of your Millipore Sigma Water Pump, consider the following: 1. Check the drain tubing to ensure it is not pinched. 2. Make sure the drain tubing isn't touching the liquid in the waste container and that the waste container is open or correctly vented. 3. Inspect the drain tray for clogs. Clean the drain tray container and support, and verify that the yellow plugs are not on the canister outlets. 4. Ensure the drain tray is positioned higher than the waste container. 5. Confirm that the tubing between the drain tray and the waste container is straight, without bends or loops.
  • P
    Peggy FlynnAug 14, 2025
    Why is my Millipore Sigma Steritest software not responding?
    • W
      William LopezAug 14, 2025
      If the software for your Millipore Sigma Water Pump is not responding, it may be due to an unexpected error. Try switching the pump off and then on again to resolve the issue.
  • G
    Gina BirdAug 19, 2025
    Why is liquid not evenly distributed between the canisters in my Millipore Sigma Water Pump?
    • J
      Julian CookAug 19, 2025
      Uneven liquid distribution between the canisters in your Millipore Sigma Water Pump can occur for a couple of reasons. One possibility is that the tubing to one of the canisters is pinched, clamped, or damaged. Open the pump head and check the tubing. Reinstall the tubing following the procedure described in Installing the Steritest® Device. Another reason could be that the filtration speed is too high, try reducing the filtration speed.
  • S
    Shirley LeAug 25, 2025
    What causes Millipore Sigma Water Pump to not recognize accessories?
    • C
      Crystal RiosAug 25, 2025
      If your Millipore Sigma Water Pump isn't recognizing accessories or data sources, it might be because they are not connected to a power source. Ensure that the accessories or data sources are properly connected to the communications hub, and that the communication hub is connected to a power source.
  • B
    Beverly CostaAug 29, 2025
    Why does the waste overfill sensor alert randomly activate on my Millipore Sigma Steritest?
    • S
      Steven PadillaAug 29, 2025
      Random waste overfill sensor alerts (red icon, beep, orange LED) on your Millipore Sigma Water Pump can be triggered if the evacuated liquid is flowing inside the rigid container in front of the sensor position. To resolve this, move the evacuation tubing away from the sensor position.

Summary

Introduction and Product Overview

System Overview and Manual Details

Introduction to the Steritest Symbio pumps, their applications, and manual scope.

Pump Versions Overview

Details of LFH, ISL, and FLEX pump versions and their installation in various environments.

Pump Assembly and Control Panel

Description of the pump's main components and its control panel interface.

Pump Setup and Operation

Additional Features and Safety

Overview of pump features, software capabilities, and essential operator safety guidelines.

Installation Procedures

Step-by-step guide for unpacking, installing the pump, communication hub, and accessories.

Using the Pump

Initial startup, filtration, operating modes, and pump states like standby/off.

Safety Mechanisms

Understanding red plugs and temperature alerts for safe pump operation.

Pump Configuration and Settings

Configuration Menu and Options

Accessing and modifying pump settings such as pressure mode, language, and calibration.

Data Transfer and Sensor Testing

Managing test methods, network setup, and performing pressure sensor verification.

Maintenance and Troubleshooting

Maintenance and Cleaning Procedures

Guidelines for ongoing maintenance, cleaning, decontamination, and reassembly.

Troubleshooting Common Issues

Guidance on resolving common pump errors, connectivity, and operational problems.

Reference Information

Accessories, Parts, and Documentation

List of available accessories, replacement parts, and user guides.

Symbols, Warranty, and Support

Explanation of product symbols, warranty information, and technical assistance contacts.

Millipore Sigma Steritest Specifications

General IconGeneral
BrandMillipore Sigma
ModelSteritest
CategoryWater Pump
LanguageEnglish