P727 (G) SCAN DELAY
Use this feature to adjust the delay before the next point is scanned. Enter the amount of delay
in seconds. This value is automatically altered when Measurement Response (P003) is altered.
( See Measurement Response ).
values: 0.000 to 60.00
P728 SHOT DELAY
Use this feature if acoustic noise within the vessel is causing measurement difficulties. Enter
the delay between transmit pulse shots ( in seconds ). This value is automatically altered
when Measurement Response ( P003 ) is altered. See TECHNICAL REFERENCE
Measurement Response.
values: 0.1 to 4.0
P729 (V) SCAN TIME
View the time elapsed ( in seconds ) since the point displayed was last scanned. This value
may be viewed as an Auxilliary Reading in the Run mode ( especially useful when setting up
Smart Scan, P720 ). See OPERATION keypad.
values: 0.000 to 9999
TECHNICAL REFERENCE
TECHNICAL REFERENCE
OPERATION