Enclosed drive
Mounting
The NEMA 4X enclosed drive comes with 0.88 inch (22mm) conduit knockout holes at
the bottom of the enclosure. The units may be vertically wall mounted using the four
0.19 inch (5 mm) slotted holes on the attached heat sink. For motor loads less than
5 ADC, the drive may be bench mounted horizontally, or operated without mounting.
Mount the drive as follows:
1. Install the mounting screws.
2. For access to the terminal strip, turn the slotted screw on the front cover
counterclockwise until it is free from the enclosure. The right side of the
cover is hinged to the enclosure. Pull the slotted screw to open the enclosure.
3. Carefully remove the conduit knockouts by tapping them into the enclosure
and twisting them off with pliers.
4. Install conduit hardware through the 0.88 inch (22 mm) knockout holes.
Connect external wiring to the terminal block.
5. Grasp the slotted screw and tilt the front cover back into place. Avoid
pinching any wires between the front cover and the enclosure.
Installation
6. Turn the slotted screw clockwise until tight to secure the front cover.
7. Set the POWER switch to the OFF position before applying AC
line voltage.