Image Optimization 5-7
IP
Description
IP is a combination of several image processing parameters, which is used for
a fast image optimization, the real-time group of which is displayed in the
image parameter area in the upper left corner of the screen.
The IP combination parameters include dynamic range, iClear, persistence,
and smooth.
Operation
Select among the IP groups through the [IP] item in the menu.
The system provides 8 groups of IP combinations, and the specific value of
each parameter can be preset.
Colorize and Colorize Map
Description
Colorize function provides an imaging process based on color difference
rather than gray distinction.
Operation
Turn on/ off the function through the [Colorize] item in the menu;
Select the colorize map through the [Colorize Map] item in the menu;
Impacts
The function is available in real-time imaging, freeze or cine review status.
TSI
Description
The TSI function is used to optimize the image by selecting acoustic speed
according to tissue characteristics.
Operation
Select among the TSI modes through the [TSI] item in the menu;
The system provided 4 ways of optimization for specific tissues: general,
muscle, fluid and fat.
iTouch
Description
To optimize image parameters as per the current tissue characteristics for a
better image effect.
Operation
Press <Gain/ iTouch> on the control panel, the iTouch symbol will display in
the image parameter area.
Click [iTouch] on the image menu to adjust gain in iTouch status among -12
through 12dB.
Gray Rejection
Description
This function is to reject image signals less than a certain gray scale, then the
rejected signal corresponding area turns black.
Operation
Click [Gray Rejection] in the menu to adjust.
The adjusting range is 0-5.
Curve
Description
To manually enhance or restrain the signal in the certain scale.
Operation
Click [Curve] in the menu to open the dialogue box to adjust.
Drag the curve node to increase or decrease the gray scale information: drag
the node up to increase the information and down to decrease.