VS 8/VS 8A Vital Signs Monitor Operator’s Manual 1 - 3
Disposable accessories are not designed to be reused. Reuse may cause a risk
of contamination and affect the measurement accuracy.
Ensure that the equipment is supplied with continuous electric power during
operation from the mains power or batteries. Sudden power failure may
cause data loss.
When no battery is installed, ensure that the monitor is supplied with
continuous electric power during operation. Sudden power failure may lead
to data loss.
Store and use the equipment in specified environmental condition. The
monitor and accessories may not meet the performance specification due to
aging, stored or used outside the specified temperature and humidity range.
Magnetic and electrical fields are capable of interfering with the proper
performance of the equipment. For this reason make sure that all external
devices operated in the vicinity of the equipment comply with the relevant
EMC requirements. Mobile phones, X-ray equipment, and MRI devices are
possible sources of interference as they may emit higher levels of
electromagnetic radiation.
Always install or carry the equipment properly to avoid damage caused by
drops, impacts, strong vibrations or other mechanical forces.
Dry the equipment immediately in case of rain or water spray.
Some settings are password protected and can only be changed by
authorized personnel. Contact your department manager or biomedical
engineering department for the passwords used at your facility.
Do not loop the patient cabling into a tight coil or wrap around the device, as
this can damage the patient cabling.
Dispose of the package material as per the applicable waste control
regulations. Keep it out of children’s reach.
At the end of its service life, the equipment, as well as its accessories, must be
disposed of in compliance with the guidelines regulating the disposal of such
products. If you have any questions concerning disposal of the equipment,
please contact Mindray.
1.1.3 Notes
NOTE
The equipment software copyright is solely owned by Mindray. No
organization or individual shall resort to modifying, copying, or exchanging
it or to any other infringement on it in any form or by any means without due
permission.
Put the equipment in a location where it can be easily viewed and operated.
1 - 4 VS 8/VS 8A Vital Signs Monitor Operator’s Manual
The equipment uses a mains plug as isolation means to the mains power. Do
not locate the equipment in a place difficult to access the mains plug.
During normal use, the operator is expected to face the front of the
equipment.
Remove the battery before shipping the monitor or if it will not be used for
an extended period of time.
The software was developed in compliance with IEC62304, to minimize the
possibility of hazards arising from software errors.
This manual is based on the maximum configuration and therefore some
contents may not apply to the product. If you have any question, please
contact Mindray.
Observance of this manual is a prerequisite for proper product performance
and correct operation and ensures patient and operator safety.
Keep this manual in the vicinity of the equipment so that it can be referenced
when needed.
1.2 Equipment Symbols
Some symbols may not appear on your equipment.
Caution
Serial number
Refer to instruction manual/
booklet
Date of manufacture
Direct current Alternating current
Battery indicator Input/output
USB connector Equipotentiality
DEFIBRILLATION-PROOF TYPE BF
APPLIED PART
DEFIBRILLATION-PROOF TYPE
CF APPLIED PART
To Purchase, Visit Avobus.com or call 1-800-674-3655

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mindray VS 8 and is the answer not in the manual?

Mindray VS 8 Specifications

General IconGeneral
BrandMindray
ModelVS 8
CategoryMonitor
LanguageEnglish

Related product manuals