Interleaf EP5000/EP4000 DIS/REASSEMBLY, ADJUSTMENT
97.04.01
D-42
(3) Replacement of the PC Drum
1136U014AA
(4) Cleaning of the Developer Scattering Prevention Plate
1136D050AA
(5) Cleaning of the Ds Positioning Collars
1136D177AA
(6) Cleaning of the Toner Antispill Trap
1136D178AA
(7) Cleaning of the Cleaning Blade
1156D167AA
1. Slide out the IU.
2. Loosen one screw and remove the stopper.
3. Remove and replace the PC Drum.
NOTE
When the PC Drum has been replaced, reset the count of
PC Drum of “Port/Option” counters of the Tech. Rep.
mode and then make the adjustment of exposure level in
the Auto Exposure mode. (For the adjustment of expo-
sure level in the Auto Exposure mode, see p. D-72.)
Using a brush, whisk dust off the Developer Scattering Pre-
vention Plate.
Using a brush or a soft cloth dampened with alcohol, clean the
Ds Positioning Collars.
Using a brush or a vacuum cleaner, clean the Toner Antispill
Trap.
Using a brush, whisk paper dust and toner off the Cleaning
Blade.