2.10 Install the hot and cold supply pipes
35 mm from the finished wall at
153 mm centres.
Use the installation template to make
sure that the pipes are in the right
position.
Note! The Combiflow is supplied with
inlet connections hot left, cold right
and bottom outlet as standard. For
installations with reversed hot and
cold supplies a reversed
temperature lever will be required.
Available from Kohler Mira
Customer Services. It is therefore
recommended that the correct pipe
orientation is achieved.
2.11Thoroughly flush the hot and cold
water supply pipes. The supplies
must be clean and free from debris
before connecting the shower
control. Failure to do so may result
in product malfunction.
2.12 Slide the compression nuts and olives
over the supply pipes.
2.13 Insert the hot and cold supply pipes
fully into the inlet nipples and slide the
olives and compression nuts into
place.
2.14 Use a suitable spanner to tighten the
compression nuts. Protect the chrome
plated surfaces with a cloth.
2.15 Refer to section: 'Commissioning
and Control Assembly Installation,
Flow Regulator Installation and
Filter Access' for details on the flow
regulator installation.
2.16 Turn on the water supplies and check
for any leaks.
2.17 Refer to section: 'Commissioning
and Control Assembly Installation'.
Olive
Compression Nut
Installation Template
For latest prices and delivery to your door visit MyTub Ltd 0845 303 8383 www.mytub.co.uk