26
3.13 Align the hot and cold supply and
outlet pipes with the valve but do not
connect to the valve.
3.14 The supplies must be clean and free
from debris before connecting the
shower control. Failure to do so
may result in product malfunction.
Note! The Combiflow is supplied with
inlet connections hot left, cold right
and top outlet as standard. For
installations with reversed hot and cold
refer to section: 'Reversed inlet
connections'.
For installations with reversed hot
and cold supplies a reversed
temperature lever will be required.
Available from Kohler Mira
Customer Services. It is therefore
recommended that the correct pipe
orientation is achieved.
3.15 Insert the hot and cold supply and
outlet pipes through the compression
nuts and olives. Make sure that each
pipe is pushed fully into the valve.
Note! For BIV outlet with falling inlet
supplies the inlet pipes may have to
be set deeper into the wall.
3.16 Hold each pipe in position and use a
suitable spanner to tighten the
compression nuts.
Compression
Nut