3 Description of functions
3-80
3.5.8. End Code
The following is a list of stored end codes.
Code category
End code
Description
Processing details
Processing
success
0000H
The request was successfully processed.
Indicates that the request was correctly
processed.
Standard error
C059H
The command or subcommand is specified
incorrectly.
A command other than the prescribed sequence
was received.
Review the command and subcommand,
and send again.
C05CH
The request message has an error.
Review the request content, and send
again.
C061H
The request data length is inconsistent with the
number of data.
Review the request data content or
request data length, and send again.
CEE1H
The request message size exceeds the allowable
range.
Review the request content, and send
again.
CEE2H
The response message size exceeds the
allowable range.
Review the request content, and send
again.