2 Preparation before use
2-10
2.2.5. Parameter setting example 2-2
(When the data link function is used: When the controller is the client)
Shows the example of the setting, when the controller is client by the data link function.
Conditions for example 2-2
Robot controller IP address
Personal computer IP address
Robot controller port No.
<For MELFA-BASIC V/VI>
Parameter setting for example 2-2
Parameter
Parameter value
NETIP
NETPORT
10000,10001,10002,10003,10004,10005,10006,10007,10008,10009
After
10000,10001,10002,10003,10004,10005,10006,10007,10008,10009
(unchanged)
CPRCE13
COMDEV
NETMODE
NETHSTIP
Before
192.168.0.2, 192.168.0.3, 192.168.0.4, 192.168.0.5, 192.168.0.6,
192.168.0.7, 192.168.0.8, 192.168.0.9, 192.168.0.10
After
192.168.0.2, 192.168.0.3, 192.168.0.2, 192.168.0.5, 192.168.0.6,
192.168.0.7, 192.168.0.8, 192.168.0.9, 192.168.0.10
Next, set the personal computer IP address to 192.168.0.10. Set this value on the Network Properties screen.
The personal computer IP address is set with the Windows TCP/IP Property Network setting (property in network
computer). Because the set-up screen differs with versions of Windows, refer to the manuals enclosed with Windows, etc.,
for details on setting this address.
Refer to the instruction manuals enclosed with the personal computer support software for details on setting and using the
personal computer support software.