3 Description of functions
3-50
Number of devices
Specify the number of devices for reading/writing data.
When performing data communication in ASCII code
Use the number of devices by converting them to 4 ASCII code digits (hexadecimal), and send them in the order
from higher-order byte to lower-order byte. Use codes in upper case characters when specifying letters of the
alphabet.
When performing data communication in binary code
Use a 2-byte numerical value to indicate the number of processing devices, and send in the order from lower-order
byte to higher-order byte.
20 devices
Example
Number of devices: 5 / 20
5 devices
5 devices
Number of devices: 5 / 20
Example
20 devices