3 Description of functions
3-55
Number of devices for bit access
This is the data required to specify the number of devices accessed in bit units.
When performing data communication in ASCII code
Convert the number of devices to 2 ASCII code digits (hexadecimal), and send them in the order from higher-order
byte to lower-order byte. Use codes in upper case characters if specifying letters of the alphabet.
When performing data communication in binary code
Convert the number of devices to hexadecimal and send.
20 devices
Example
Number of devices: 5 / 20
5 devices
20 devices
Example
Number of devices: 5 / 20
5 devices