3 System Configuration
3.2 Devices Required for Network Configuration
22
FX3U-ENET-ADP User's Manual
3.2 Devices Required for Network Configuration
This section explains the devices that are required to configure a network.
Network installation work requires sufficient safeguards; ask a network specialist for installation.
When connecting the Ethernet adapter to a network, either 10BASE-T or 100BASE-TX can be used.
The Ethernet adapter detects whether it is 10BASE-T or 100BASE-TX, and full-duplex or half-duplex
transmission mode according to the hub. (Auto detection function)
For connection to the hub without the auto detection function, set half-duplex mode on the hub side.
1) Connection using 100BASE-TX
Use devices that satisfy the standards of IEEE802.3 and 100BASE-TX.
Shielded twisted pair cable (STP cable), category 5 or better
Use a straight cable for connection between a hub and the Ethernet adapter.
(A cross cable can also be used when connecting the Ethernet adapter directly to the external device,
not through a hub.)
RJ45 plug
100Mbps hub
2) Connection using 10BASE-T
Use devices that satisfy the standards of IEEE802.3 and 10BASE-T.
Use devices that satisfy the standards of IEEE802.3 and 100BASE-TX.
Shielded twisted pair cable (STP cable), category 3 or better
Use a straight cable for connection between a hub and the Ethernet adapter.
(A cross cable can also be used when connecting the Ethernet adapter directly to the external device,
not through the hub.)
RJ45 plug
10Mbps hub
3.3 Applicable Systems
3.3.1 Applicable PLC
The version number can be checked by reading the last three digits of device D8001 or D8101.
*1. An expansion board is required to connect the FX
3U-ENET-ADP with FX3U/FX3UC-32MT-LT(-2) PLCs.
3.3.2 Applicable Software
1. GX Works2
Use the following version when setting the Ethernet adapter or using the MELSOFT connection function.
Caution
If an older version is used, programming will not be possible.
In order to set up the Ethernet adapter via GX Works2, FX Configurator-EN needs to be installed.
Model name Applicability
FX
3U Series PLC
*1
Ver. 3.10 and later
Only one FX3U-ENET-ADP unit can be connected to a main unit.
FX3UC Series PLC
*1
Ver. 3.10 and later
Only one FX3U-ENET-ADP unit can be connected to a main unit.
Software Applicability
GX Works2
SW DNC-GXW2-E
Ver. 1.73B or later