FX3G/FX3U/FX3UC Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
2 Overview (Sequence Program)
2.2 Introduction of Applied Instructions
2.2.1 Major applied instructions
This subsection introduces representative ones among many applied instructions.
1. Program flow
Conditional jump (CJ/FNC 00)
Call subroutine (CALL/FNC 01)
Enable interrupt (EI/FNC 04)
Disable interrupt (DI/FNC 05)
Start a FOR/NEXT loop (FOR/FNC 08)
Refer to Chapter 8.
2. Move and compare
Compare (CMP/FNC 10)
Data comparison (FNC224 to FNC246)
Floating point compare
(ECMP/FNC110 and EZCP/FNC111)
Zone compare (ZCP/FNC 11)
High speed counter compare
(FNC 53 to FNC 55)
High speed counter compare with data table
(HSCT/FNC280)
Move (MOV/FNC 12)
Floating point move (EMOV/FNC112)
High speed counter move (HCMOV/FNC189)
Conversion to binary-coded decimal
(BCD/FNC 18)
Conversion to binary (BIN/FNC 19)
Decimal to gray code conversion (FNC170)
and gray code to decimal conversion
(FNC171)
Refer to Chapter 9, Chapter 13, Chapter 18,
Chapter 22, Chapter 24, Chapter 28 and
Chapter 32.
3. Arithmetic and logical operations
Addition (ADD/FNC 20)
Subtraction (SUB/FNC 21)
Multiplication (MUL/FNC 22)
Division (DIV/FNC 23)
Increment (INC/FNC 24)
Square root (SQR/FNC 48)
Trigonometry (FNC130 to FNC135)
Conversion from/to floating point
(FNC 49, FNC118, FNC119 and FNC129)
Floating point arithmetic operations
(FNC120 to FNC123)
Floating point square root (ESQR/FNC127)
Refer to Chapter 10, Chapter 12 and
Chapter 18.
4. Rotation and shift operation
Rotation right (ROR/FNC 30)
Rotation left (ROL/FNC 31)
Rotation right with carry (RCR/FNC 32)
Rotation left with carry (RCL/FNC 33)
Bit shift right (SFTR/FNC 34)
Bit shift left (SFTL/FNC 35)
Word shift right (WSFR/FNC 36)
Word shift left (WSFL/FNC 37)
Refer to Chapter 11.
5. Data operation
Zone reset (ZRST/FNC 40)
Decode (DECO/FNC 41)
Encode (ENCO/FNC 42)
Sum of active bits (SUM/FNC 43)
Mean (MEAN/FNC 45)
Word to byte (WTOB/FNC141) and byte to
word (BTOW/FNC142)
4-bit linking/grouping of word data
(FNC143 and FNC144)
Limit control (LIMIT/FNC256)
Dead band control (BAND/FNC257)
Zone control (ZONE/FNC258)
Block data operation (FNC192 to FNC199)
Character string control (FNC200 to FNC209)
Refer to Chapter 12, Chapter 19,
Chapter 25, Chapter 26 and Chapter 29.
6. High speed processing
Refresh (REF/FNC 50)
Refresh and filter adjust (REFF/FNC 51)
Speed detection (SPD/FNC 56)
Pulse Y output (PLSY/FNC 57)
Pulse ramp (PLSR/FNC 59)
Refer to Chapter 13.
7. Handy instructions and instructions for
external devices
Initial state (IST/FNC 60)
Teaching timer (TTMR/FNC 64)
Alternate state (ALT/FNC 66)
Ramp variable value (RAMP/FNC 67)
Rotary table control (ROTC/FNC 68)
Ten-key input (TKY/FNC 70)
Digital switch (thumbwheel input)
(DSW/FNC 72)
Seven-segment decoder (SEGD/FNC 73)
Seven-segment with latch (SEGL/FNC 74)